1.
Int J Lab Hematol ; 46(3): 555-560, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38319015

RESUMO

INTRODUCTION: The Thai National Guidelines for Hemostatic Laboratory Testing were established in 2018. The guidelines recommend that the 20-min whole blood clotting time (20WBCT) method be used to diagnose/monitor snake bites. The aim of this study was to survey members of the Thailand National External Quality Assessment Scheme (NEQAS) for Blood Coagulation to investigate the use of 20WBCT testing compared between the 2021 post-guideline and 2007 pre-guideline periods. METHODS: In July 2021, questionnaires were sent from the Faculty of Medicine Siriraj Hospital, Mahidol University to 521 Thailand NEQAS for Blood Coagulation member laboratories to survey their WBCT practices. Current WBCT practices were compared with pre-guideline WBCT practices, and chi-square test (x2) was used to test for differences between groups. RESULTS: Ninety-seven (18.6%) of 521 surveys were returned. Seventy-one laboratories (73.2%) reported knowing about 20WBCT from the Thai national guidelines. The reported average frequency of overall WBCT testing in 2021 was 12.4 times/month. The proportion of laboratories that reported using the 20WBCT test increased from 2.0% in 2007 to 46.4% in 2021 (p < 0.001), and the indications for performing WBCT were virtually unchanged from 2007 to 2021. The proportion of laboratories that reported having problems with WBCT testing decreased from 32.7% in 2007 to 16.5% in 2021. CONCLUSION: Despite our findings that almost three-quarters of respondent laboratories reported knowing about 20WBCT testing from the WBCT guidelines, and that WBCT-specific problems decreased significantly from 2007 to 2021, more work and training is needed to improve WBCT guideline dissemination, understanding, and adherence in Thailand.


Assuntos
Coagulação Sanguínea , Humanos , Tailândia , Tempo de Coagulação do Sangue Total/normas , Inquéritos e Questionários , Garantia da Qualidade dos Cuidados de Saúde , Guias de Prática Clínica como Assunto , Laboratórios Clínicos/normas
2.
Scand J Clin Lab Invest ; 83(7): 470-478, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37815437

RESUMO

OBJECTIVES: There appears to be marked discrepancies between total IgE reference intervals (RIs) in use by many laboratories and those recommended by published studies. The aim of this study was therefore to review total IgE RIs currently reported by Scandinavian and British laboratories and to compare these to published RIs identified by a literature review. METHODS: Relevant laboratories were identified by test directories provided by the national accreditation bodies in Norway, Sweden, Denmark and the UK. Total IgE RIs and their sources were acquired by accessing laboratory user handbooks or by an electronic survey. In addition a literature review of published total IgE RI studies was performed. RESULTS: From 172 accredited laboratories providing total IgE analysis, data was acquired from 122 laboratories. An adult upper reference limit between 81 to 150 kU/L was reported by 89% of these. Denmark and Sweden reported the most harmonised RIs whilst Norway and the UK exhibited the least degree of harmonisation. Published adult (n = 6) and paediatric (n = 6) RI studies reported markedly higher upper limits than those currently in use by the laboratories included in this study. There were also large variations in the number of age strata in use for paediatric RIs. CONCLUSION: This study demonstrates large variations in currently utilised IgE RIs by Scandinavian and British accredited laboratories and most report markedly lower RIs than those recommended by recent RI publications. Many laboratories likely utilise outdated RIs and should consider critically reviewing and updating their RIs.


Assuntos
Imunoglobulina E , Laboratórios Clínicos , Adulto , Criança , Humanos , Valores de Referência , Inquéritos e Questionários , Países Escandinavos e Nórdicos , Reino Unido , Laboratórios Clínicos/normas
3.
J Clin Lab Anal ; 37(11-12): e24929, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37431092

RESUMO

AIM: The study objective was to evaluate the performance of sthemO 301 system and to compare it with the analyzer used in our university hospital laboratory (STA R Max® 2), for a selection of hemostasis parameters. METHODS: Method comparison (according to CLSI EP09-A3), carryover (according to CLSI H57-A), APTT sensitivity to heparin (according to CLSI H47-A2), HIL level assessment, and productivity were performed using leftover samples from our laboratory (n > 1000). Commercial quality control materials were used to evaluate precision (according to CLSI EP15-A3) and accuracy. The assays tested on sthemO 301 were: PT, APTT (silica and kaolin activators), fibrinogen (Fib), thrombin time (TT), chromogenic and clotting protein C (PC) activity, and von Willebrand factor antigen (VWF:Ag) levels. RESULTS: All intra-assay and inter-assay precision CVs were below the maximal precision limit proposed by the French Group for Hemostasis and Thrombosis (GFHT). Accuracy was verified with bias below GFHT criteria and most Z-scores were between -2 and +2. No clinically relevant carryover was detected. Silica APTT reagent sensitivity to unfractionated heparin was moderate, as expected. Productivity results were consistent over the 10 repeats performed. The overall agreement between the two systems was excellent for all assays, with Spearman rank correlation coefficient all above 0.9 and slopes of Passing-Bablok correlation near 1 and intercepts close to 0. CONCLUSION: For the methods tested, sthemO 301 system met all the criteria to implement a novel coagulation analyzer in the laboratory and result comparability with STA R Max® 2 was good.


Assuntos
Testes de Coagulação Sanguínea , Laboratórios Clínicos , Humanos , Testes de Coagulação Sanguínea/instrumentação , Heparina/análise , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Laboratórios Clínicos/normas
5.
JAMA ; 328(20): 2060-2062, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-36413243

RESUMO

This study includes clinical laboratories that participated in the first general chemistry proficiency testing survey in 2022 to assess awareness and adoption of new equations from the Chronic Kidney Disease Epidemiology Collaboration for estimated glomerular filtration rate (eGFR) that eliminated race-adjustment factors, including one based on creatinine and one based on creatinine and cystatin C.


Assuntos
Serviços de Laboratório Clínico , Taxa de Filtração Glomerular , Fidelidade a Diretrizes , Laboratórios Clínicos , Serviços de Laboratório Clínico/normas , Creatinina , Laboratórios Clínicos/normas , Estados Unidos , Conhecimentos, Atitudes e Prática em Saúde
6.
Can J Cardiol ; 38(8): 1180-1188, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35378262

RESUMO

There is limited guidance on laboratory reporting and interpretation of lipids and lipoproteins used in cardiovascular risk stratification. This contributes to inconsistencies in lipid reporting across clinical laboratories. Recently, the Canadian Cardiovascular Society (CCS) published the 2021 CCS guidelines for the management of dyslipidemia for the prevention of cardiovascular disease in the adult. A subcommittee of the Working Group on Reference Interval Harmonization of the Canadian Society of Clinical Chemists has developed harmonized lipid reporting recommendations that are aligned with the 2021 CCS guidelines, to improve the standardization of lipid assessment and clinical decision-making. The proposed harmonized lipid reporting recommendations were critically reviewed by a broad range of laboratory and clinical experts across Canada. Feedback from approximately 30 expert reviewers was reviewed by the Working Group on Reference Interval Harmonization lipid subcommittee, and consensus decisions were incorporated into the 2021 harmonized lipid reporting recommendations. In this position statement, we provide 6 recommendations for laboratory reporting of lipid parameters. These recommendations include implementing the new National Institutes of Health equation to replace the Friedewald equation for calculating low-density lipoprotein cholesterol, offering lipoprotein (a), either as an in-house or send-out test, and using assays that report lipoprotein (a) in molar units (nmol/L). We also developed a harmonized lipid reporting format with interpretive comments that includes flagging results based on screening patients using treatment decision thresholds in a primary prevention setting. Overall, harmonized lipid reporting will help bridge the gap between clinical guideline recommendations and clinical laboratory reporting and interpretation, and will improve cardiovascular risk assessment across Canada.


Assuntos
Dislipidemias , Laboratórios Clínicos , Lipídeos , Adulto , Canadá/epidemiologia , Doenças Cardiovasculares/prevenção & controle , Dislipidemias/diagnóstico , Fatores de Risco de Doenças Cardíacas , Humanos , Laboratórios Clínicos/normas , Lipídeos/análise , Lipoproteína(a)
7.
J Clin Lab Anal ; 36(1): e24069, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34783398

RESUMO

BACKGROUND: This study aimed to investigate the implementation and quality control of the quantitative detection of serum Helicobacter pylori (H. pylori) antibody in clinical laboratories in China. METHODS: Online external quality assessment (EQA) questionnaires were distributed to the clinical laboratories by National Center for Clinical Laboratories (NCCL) of China. We collected information on the quantitative detection procedures of serum H. pylori antibody in clinical laboratories, including detection reagents, methods, instruments, calibrators, and internal quality control (IQC). We distributed quality control products to some select laboratories that conducted quantitative detection and analyzed the obtained test data. We evaluated the quantitative detection procedure based on the standard evaluation criteria set at a target value of ±30%. RESULTS: 70.9% (146/206) of the laboratories conducted quantitative detection of H. pylori antibody; 29.1% (60/206) of the laboratories performed qualitative detection. Domestic reagents and matching calibrators accounted for more than 97.1% (200/206) of all reagents. Latex-enhanced immunoturbidimetry was used in 89.7% (131/146) of the laboratories for quantitative determination, while the colloidal gold method was used in 66.7% (40/60) of the laboratories for qualitative determination. A total of 130 laboratories participated in the EQA; 123 completed the assessment, and the pass rate was 75.6% (93/123). CONCLUSION: Clinical quantitative detection of serum H. pylori antibody is performed at a high rate in China. Thus, further studies on the specificity of commercial detection reagents are needed. EQAs are useful to monitor and improve the detection quality of H. pylori antibodies.


Assuntos
Anticorpos Antibacterianos/sangue , Helicobacter pylori/imunologia , Laboratórios Clínicos , China , Infecções por Helicobacter/diagnóstico , Infecções por Helicobacter/imunologia , Infecções por Helicobacter/microbiologia , Humanos , Imunoturbidimetria/normas , Laboratórios Clínicos/normas , Laboratórios Clínicos/estatística & dados numéricos , Controle de Qualidade , Inquéritos e Questionários
8.
Matola; Instituto Nacional de Saúde; 2022. 196 p. tab, fig.
Não convencional em Português | RDSM | ID: biblio-1517309

RESUMO

A Biossegurança e Bioprotecção em Laboratórios de Saúde Pública, Laboratórios de Análises Clínicas e instituções de pesquisa em saúde são áreas do conhecimento relativamente novas, reguladas em vários países por um conjunto de leis, normas, directrizes e procedimentos específicos. Actualmente, a Biossegurança e a Bioprotecção são vistas como disciplinas científicas que requerem um domínio de conhecimentos, habilidades e atitudes (CHA) multi-disciplinares. A aplicação dos princípios de Biossegurança e Bioprotecção é essencial para conter, prevenir, reduzir e eliminar os riscos de exposição por agentes microbiológicos, químicos, físicos, ergonómicos, acidentais e entre outros perigos que podem ou poderiam causar doenças de âmbito ocupacional. A Biossegurança e a Bioprotecção são também importantes para prevenir a exposição a riscos aos familiares de profissionais de saúde, utentes dos serviços de saúde, e para garantir a protecção do meio ambiente e da vida selvagem


Assuntos
Humanos , Masculino , Feminino , Contenção de Riscos Biológicos/normas , Laboratórios Clínicos/normas , Pessoal de Saúde/estatística & dados numéricos , Bancos de Espécimes Biológicos/organização & administração , Contenção de Riscos Biológicos/instrumentação , Contenção de Riscos Biológicos/métodos , Técnicas de Laboratório Clínico/métodos , Elementos Químicos , Equipamentos e Provisões/provisão & distribuição , Fenômenos Microbiológicos/efeitos da radiação , Moçambique
9.
J Clin Lab Anal ; 35(12): e24087, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34724262

RESUMO

BACKGROUND: The measurement method for experimental resolution and related data to evaluate analytical performance is poorly explored in clinical research. We established a method to measure the experimental resolution of clinical tests, including biochemical tests, automatic hematology analyzer methods, immunoassays, chemical experiments, and qPCR, to evaluate their analytical performance. METHODS: Serially diluted samples in equal proportions were measured, and correlation analysis was performed between the relative concentration and the measured value. Results were accepted for p ≤ 0.01 of the correlation coefficient. The minimum concentration gradient (eg, 10%) was defined as the experimental resolution. For this method, the smaller the value, the higher the experimental resolution and the better the analytical performance. RESULTS: The experimental resolution of the most common biochemical indices reached 10%, with some even reaching 1%. The results of most counting experiments showed experimental resolution up to 10%, whereas the experimental resolution of the classical chemical assays reached 1%. Unexpectedly, the experimental resolution of more sensitive assays, such as immunoassays was only 25% when using the manual method and 10% for qPCR. CONCLUSION: This study established a method for measuring the experimental resolution of laboratory assays and provides a new index for evaluating the reliability of methods in clinical laboratories.


Assuntos
Análise Química do Sangue/métodos , Técnicas Imunológicas/métodos , Laboratórios Clínicos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Contagem de Células Sanguíneas , Análise Química do Sangue/normas , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Técnicas Imunológicas/normas , Laboratórios Clínicos/normas , Reação em Cadeia da Polimerase em Tempo Real/normas , Reprodutibilidade dos Testes , Espectrofotometria Atômica
10.
Parkinsonism Relat Disord ; 92: 107-111, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34696975

RESUMO

INTRODUCTION: There have been no specific guidelines regarding which genes should be tested in the clinical setting for Parkinson's disease (PD) or parkinsonism. We evaluated the types of clinical genetic testing offered for PD as the first step of our gene curation. METHODS: The National Institutes of Health (NIH) Genetic Testing Registry (GTR) was queried on 12/7/2020 to identify current commercial PD genetic test offerings by clinical laboratories, internationally. RESULTS: We identified 502 unique clinical genetic tests for PD, from 28 Clinical Laboratory Improvement Amendments (CLIA)-approved clinical laboratories. These included 11 diagnostic PD panels. The panels were notable for their differences in size, ranging from 5 to 62 genes. Five genes for variant query were included in all panels (SNCA, PRKN, PINK-1, PARK7 (DJ1), and LRRK2). Notably, the addition of the VPS35 and GBA genes was variable. Panel size differences stemmed from inclusion of genes linked to atypical parkinsonism and dystonia disorders, and genes in which the link to PD causation is controversial. CONCLUSION: There is an urgent need for expert opinion regarding which genes should be included in a commercial laboratory multi-gene panel for PD.


Assuntos
Predisposição Genética para Doença/genética , Testes Genéticos/tendências , Laboratórios Clínicos/estatística & dados numéricos , Doença de Parkinson/genética , Testes Genéticos/métodos , Testes Genéticos/normas , Humanos , Laboratórios Clínicos/normas
11.
J Clin Lab Anal ; 35(11): e24059, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34652033

RESUMO

BACKGROUND: The six sigma model has been widely used in clinical laboratory quality management. In this study, we first applied the six sigma model to (a) evaluate the analytical performance of urinary biochemical analytes across five laboratories, (b) design risk-based statistical quality control (SQC) strategies, and (c) formulate improvement measures for each of the analytes when needed. METHODS: Internal quality control (IQC) and external quality assessment (EQA) data for urinary biochemical analytes were collected from five laboratories, and the sigma value of each analyte was calculated based on coefficients of variation, bias, and total allowable error (TEa). Normalized sigma method decision charts for these urinary biochemical analytes were then generated. Risk-based SQC strategies and improvement measures were formulated for each laboratory according to the flowchart of Westgard sigma rules, including run sizes and the quality goal index (QGI). RESULTS: Sigma values of urinary biochemical analytes were significantly different at different quality control levels. Although identical detection platforms with matching reagents were used, differences in these analytes were also observed between laboratories. Risk-based SQC strategies for urinary biochemical analytes were formulated based on the flowchart of Westgard sigma rules, including run size and analytical performance. Appropriate improvement measures were implemented for urinary biochemical analytes with analytical performance lower than six sigma according to the QGI calculation. CONCLUSIONS: In multilocation laboratory systems, a six sigma model is an excellent quality management tool and can quantitatively evaluate analytical performance and guide risk-based SQC strategy development and improvement measure implementation.


Assuntos
Laboratórios Clínicos/normas , Gestão da Qualidade Total , Urinálise , Biomarcadores/urina , Humanos , Controle de Qualidade , Padrões de Referência , Urinálise/métodos , Urinálise/normas
12.
Int J Lab Hematol ; 43(6): 1272-1283, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34581008

RESUMO

This guidance document has been prepared on behalf of the International Council for Standardization in Haematology (ICSH). The aim of the document is to provide guidance and recommendations for the processing of citrated blood samples for coagulation tests in clinical laboratories in all regions of the world. The following areas are included in this document: Sample transport including use of pneumatic tubes systems; clots in citrated samples; centrifugation; primary tube storage and stability; interfering substances including haemolysis, icterus and lipaemia; secondary aliquots-transport, storage and processing; preanalytical variables for platelet function testing. The following areas are excluded from this document, but are included in an associated ICSH document addressing collection of samples for coagulation tests in clinical laboratories; ordering tests; sample collection tube and anticoagulant; preparation of the patient; sample collection device; venous stasis before sample collection; order of draw when different sample types are collected; sample labelling; blood-to-anticoagulant ratio (tube filling); influence of haematocrit. The recommendations are based on published data in peer-reviewed literature and expert opinion.


Assuntos
Testes de Coagulação Sanguínea/normas , Hematologia/normas , Testes de Coagulação Sanguínea/métodos , Coleta de Amostras Sanguíneas/métodos , Coleta de Amostras Sanguíneas/normas , Hematologia/métodos , Humanos , Laboratórios Clínicos/normas , Padrões de Referência
13.
Diagn Microbiol Infect Dis ; 101(3): 115488, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34461499

RESUMO

A common strategy in antifungal susceptibility testing is the utilization of the standardized protocol based on the microbroth dilution assay approach as described by the Clinical Laboratory Standards Institute (CLSI) (M27-A4). One major problem for laboratories in resource-limited countries with this protocol arises from the use of expensive culture media like RPMI-1640 and 3-N-morpholinopropanesulfonic acid (MOPS) buffer. One approach of circumventing this problem in cases of economic need is the evaluation of alternative culture media and buffers. The overall goal of this work was to investigate the influence of modifications in the protocol M27-A4 on diagnostic reliability. We performed univariate analyses evaluating (1) 2 different culture media (YNB and modified SAB); (2) three different buffers (sodium bicarbonate, Tris-HCL, and phosphate), as well as the influence of inoculum concentration (102, 103, 104, 105 cells/mL), the influence of incubation time, and the influence of the assessment mode (visual, biological dye, and spectrophotometer). Our results suggested that (1) RPMI-1640 may be substituted by modified SAB and (2) MOPS buffer may be substituted by Tris-HCl buffer for defined analyses. By comparing the CLSI protocol and the alternative protocol proposed in the present study (modified SAB and Tris-HCl buffer) for the assessment of fluconazole susceptibility of eighteen yeasts (clinical isolates), similar results with both methodologies were recorded. We feel that this study should stimulate a discussion on the feasibility and evolution of the M27-A4 protocol in order to include pragmatic alternatives for resource-limited settings.


Assuntos
Antifúngicos/farmacologia , Meios de Cultura/química , Fungos/efeitos dos fármacos , Testes de Sensibilidade Microbiana/normas , Soluções Tampão , Serviços de Laboratório Clínico , Fungos/classificação , Humanos , Laboratórios Clínicos/normas , Testes de Sensibilidade Microbiana/métodos , Reprodutibilidade dos Testes
14.
Hum Immunol ; 82(11): 838-849, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34404545

RESUMO

BACKGROUND AND PURPOSE: Currently there are no widely accepted guidelines for chimerism analysis testing in hematopoietic cell transplantation (HCT) patients. The objective of this review is to provide a practical guide to address key aspects of performing and utilizing chimerism testing results. In developing this guide, we conducted a survey of testing practices among laboratories that are accredited for performing engraftment monitoring/chimerism analysis by either the American Society for Histocompatibility & Immunogenetics (ASHI) and/or the European Federation of Immunogenetics (EFI). We interpreted the survey results in the light of pertinent literature as well as the experience in the laboratories of the authors. RECENT DEVELOPMENTS: In recent years there has been significant advances in high throughput molecular methods such as next generation sequencing (NGS) as well as growing access to these technologies in histocompatibility and immunogenetics laboratories. These methods have the potential to improve the performance of chimerism testing in terms of sensitivity, availability of informative genetic markers that distinguish donors from recipients as well as cost. SUMMARY: The results of the survey revealed a great deal of heterogeneity in chimerism testing practices among participating laboratories. The most consistent response indicated monitoring of engraftment within the first 30 days. These responses are reflective of published literature. Additional clinical indications included early detection of impending relapse as well as identification of cases of HLA-loss relapse.


Assuntos
Transplante de Células-Tronco Hematopoéticas , Sequenciamento de Nucleotídeos em Larga Escala/estatística & dados numéricos , Teste de Histocompatibilidade/estatística & dados numéricos , Laboratórios Clínicos/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Quimerismo , Sequenciamento de Nucleotídeos em Larga Escala/normas , Teste de Histocompatibilidade/métodos , Teste de Histocompatibilidade/normas , Humanos , Laboratórios Clínicos/normas , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/normas , Inquéritos e Questionários/estatística & dados numéricos , Quimeras de Transplante/genética , Quimeras de Transplante/imunologia , Transplante Homólogo
15.
J Immunother Cancer ; 9(7)2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34266881

RESUMO

BACKGROUND: Emerging data suggest predictive biomarkers based on the spatial arrangement of cells or coexpression patterns in tissue sections will play an important role in precision immuno-oncology. Multiplexed immunofluorescence (mIF) is ideally suited to such assessments. Standardization and validation of an end-to-end workflow that supports multisite trials and clinical laboratory processes are vital. Six institutions collaborated to: (1) optimize an automated six-plex assay focused on the PD-1/PD-L1 axis, (2) assess intersite and intrasite reproducibility of staining using a locked down image analysis algorithm to measure tumor cell and immune cell (IC) subset densities, %PD-L1 expression on tumor cells (TCs) and ICs, and PD-1/PD-L1 proximity assessments. METHODS: A six-plex mIF panel (PD-L1, PD-1, CD8, CD68, FOXP3, and CK) was rigorously optimized as determined by quantitative equivalence to immunohistochemistry (IHC) chromogenic assays. Serial sections from tonsil and breast carcinoma and non-small cell lung cancer (NSCLC) tissue microarrays (TMAs), TSA-Opal fluorescent detection reagents, and antibodies were distributed to the six sites equipped with a Leica Bond Rx autostainer and a Vectra Polaris multispectral imaging platform. Tissue sections were stained and imaged at each site and delivered to a single site for analysis. Intersite and intrasite reproducibility were assessed by linear fits to plots of cell densities, including %PDL1 expression by TCs and ICs in the breast and NSCLC TMAs. RESULTS: Comparison of the percent positive cells for each marker between mIF and IHC revealed that enhanced amplification in the mIF assay was required to detect low-level expression of PD-1, PD-L1, FoxP3 and CD68. Following optimization, an average equivalence of 90% was achieved between mIF and IHC across all six assay markers. Intersite and intrasite cell density assessments showed an average concordance of R2=0.75 (slope=0.92) and R2=0.88 (slope=0.93) for breast carcinoma, respectively, and an average concordance of R2=0.72 (slope=0.86) and R2=0.81 (slope=0.68) for NSCLC. Intersite concordance for %PD-L1+ICs had an average R2 value of 0.88 and slope of 0.92. Assessments of PD-1/PD-L1 proximity also showed strong concordance (R2=0.82; slope=0.75). CONCLUSIONS: Assay optimization yielded highly sensitive, reproducible mIF characterization of the PD-1/PD-L1 axis across multiple sites. High concordance was observed across sites for measures of density of specific IC subsets, measures of coexpression and proximity with single-cell resolution.


Assuntos
Biomarcadores Tumorais/metabolismo , Imunofluorescência/métodos , Imuno-Histoquímica/métodos , Laboratórios Clínicos/normas , Análise Serial de Tecidos/métodos , Feminino , Humanos , Masculino
16.
Pathology ; 53(7): 902-911, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34274166

RESUMO

The adoption of whole genome sequencing (WGS) data over the past decade for pathogen surveillance, and decision-making for infectious diseases has rapidly transformed the landscape of clinical microbiology and public health. However, for successful transition to routine use of these techniques, it is crucial to ensure the WGS data generated meet defined quality standards for pathogen identification, typing, antimicrobial resistance detection and surveillance. Further, the ongoing development of these standards will ensure that the bioinformatic processes are capable of accurately identifying and characterising organisms of interest, and thereby facilitate the integration of WGS into routine clinical and public health laboratory setting. A pilot proficiency testing (PT) program for WGS of infectious agents was developed to facilitate widely applicable standardisation and benchmarking standards for WGS across a range of laboratories. The PT participating laboratories were required to generate WGS data from two bacterial isolates, and submit the raw data for independent bioinformatics analysis, as well as analyse the data with their own processes and answer relevant questions about the data. Overall, laboratories used a diverse range of bioinformatics tools and could generate and analyse high-quality data, either meeting or exceeding the minimum requirements. This pilot has provided valuable insight into the current state of genomics in clinical microbiology and public health laboratories across Australia. It will provide a baseline guide for the standardisation of WGS and enable the development of a PT program that allows an ongoing performance benchmark for accreditation of WGS-based test processes.


Assuntos
Bactérias/genética , Benchmarking/normas , Genoma Bacteriano/genética , Laboratórios/normas , Sequenciamento Completo do Genoma/normas , Acreditação , Austrália/epidemiologia , Genômica , Humanos , Laboratórios Clínicos/normas , Ensaio de Proficiência Laboratorial , Saúde Pública
17.
Clin Biochem ; 97: 78-81, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34329621

RESUMO

In the field of laboratory medicine, proficiency testing is a vehicle used to improve the reliability of reported results. When proficiency tests are unavailable for a given analyte, an alternative approach is required to ensure adherence to the International Organization for Standardization (ISO) 15189:2012 standard. In this study, we report the results of a split-sample testing program performed as an alternative to a formal PT. This testing method was based on recommendations provided in the Clinical and Laboratory Standards Institute (CLSI) QMS24 guideline. Two different laboratories measured, in duplicate, the heparan sulfate concentration in five samples using ultra-performance liquid chromatography and tandem mass spectrometry. The data analysis to determine the criterion used for the comparability assessment between the two laboratories was based on Appendix E of the QMS24 guideline. Mean interlaboratory differences fell within the maximum allowable differences calculated from the application of the QMS24 guideline, indicating that the results obtained by the two laboratories were comparable across the concentrations tested. Application of the QMS24 split-sample testing procedure allows laboratories to objectively assess test results, thus providing the evidence needed to face an accreditation audit with confidence. However, due to the limitations of statistical analyses in small samples (participants and/or materials), laboratory specialists should assess whether the maximum allowable differences obtained are suitable for the intended use, and make adjustments if necessary.


Assuntos
Laboratórios Clínicos/normas , Ensaio de Proficiência Laboratorial/métodos , Controle de Qualidade , Cromatografia Líquida/normas , Heparitina Sulfato/análise , Heparitina Sulfato/sangue , Humanos , Espectrometria de Massas em Tandem/normas
18.
J Clin Lab Anal ; 35(8): e23878, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34165837

RESUMO

BACKGROUND: To evaluate the utility of the process capability indices Cp and Cpk for assessing the quality control processes at chain laboratory facilities. METHODS: In April 2020, the minimum Cp and Cpk values for 33 assays of a laboratory chain with 19 facilities were collected for further analysis and a total of 627 datasets (Cp and Cpk ) were compared. In addition, standard values for Cp and Cpk , defined as the lowest of the top 20%, were obtained for comparison and the indices were used to determine whether precision or trueness improvements were required for the corresponding assay. RESULTS: A total of 627 datasets of 33 assays from 19 laboratory facilities were collected for further analysis. Based on the Cp results, 329 (52.5%), 211 (33.7%), 65 (10.3%), and 22 (3.5%) were rated as excellent, good, marginal, and poor, respectively. While the corresponding results for Cpk were 300 (47.8%), 216 (34.4%), 79 (12.6%), and 32 (5.1%). In addition, it was noteworthy that eight (Cp criteria) and six assays (Cpk criteria) were rated as excellent or good at all 19 facilities. Comparison of the process capability indices at the Jinan KingMed Center with the standard values revealed that total protein, albumin, and urea showed trueness individual improvement, precision individual improvement, and precision common improvement, respectively, while the results of other assays were stable. CONCLUSION: Process capability indices are useful for evaluating the quality control procedures in laboratory facilities and can help improve the precision and trueness of laboratory tests.


Assuntos
Laboratórios Clínicos/normas , Controle de Qualidade , Análise Química do Sangue/normas , China , Humanos
19.
Scand J Clin Lab Invest ; 81(3): 218-224, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33755506

RESUMO

The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) published the reference measurement procedure (RMP) for ALP measurement in 2011. However, the RMP is of high requirements for laboratories, complicated, time-consuming and high cost of reagents. Many manufacturers do not trace results to the higher procedure. And there is currently no designated comparison method (DCM) for ALP measurement. Thus, the standardization of ALP measurement is hindered. Automatic biochemical analyzers are easy to operate and widely used in clinical laboratories. Therefore, according to the RMP, establishing a DCM based on an automatic biochemical analyzer will be a practical way to establish traceability to the accuracy base and promote the standardization of ALP measurement. On the basis of conforming to the RMP recommended by IFCC as far as possible, the DCM was established based on a Thermo Indiko automatic biochemical analyzer. Performances of the method were validated. The DCM repeatability and within laboratory imprecision was <1% and <2.5%, respectively. For evaluation of trueness, the biases were within the equivalent limits. Measurement procedure comparisons and biases estimation were carried out between the DCM, the RMP, and the six routine methods using a panel of 40 individual human serum samples. The comparisons between the DCM and the RMP gave satisfying results. Compared with the DCM, the relative biases of some routine methods failed to meet the bias limit derived from biological variation.


Assuntos
Fosfatase Alcalina/sangue , Análise Química do Sangue/métodos , Análise Química do Sangue/instrumentação , Análise Química do Sangue/normas , Humanos , Laboratórios Clínicos/normas , Reprodutibilidade dos Testes
20.
Eur J Hum Genet ; 29(4): 541-552, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33311710

RESUMO

Participation of clinical genetic laboratories in External Quality Assessment schemes (EQAs) is a powerful method to ascertain if any improvement or additional training is required in the diagnostic service. Here, we provide evidence from recent EQAs that the competence in recognizing and interpreting cytogenetic aberrations is variable and could impact patient management. We identify several trends that could affect cytogenomic competence. Firstly, as a result of the age distribution among clinical laboratory geneticists (CLGs) registered at the European Board of Medical Genetics, about 25-30% of those with experience in cytogenetics will retire during the next decade. At the same time, there are about twice as many molecular geneticists to cytogeneticists among the younger CLGs. Secondly, when surveying training programs for CLG, we observed that not all programs guarantee that candidates gather sufficient experience in clinical cytogenomics. Thirdly, we acknowledge that whole genome sequencing (WGS) has a great attraction to biomedical scientists that wish to enter a training program for CLG. This, with a larger number of positions available, makes a choice for specialization in molecular genetics logical. However, current WGS technology cannot provide a diagnosis in all cases. Understanding the etiology of chromosomal rearrangements is essential for appropriate follow-up and for ascertaining recurrence risks. We define the minimal knowledge a CLG should have about cytogenomics in a world dominated by WGS, and discuss how laboratory directors and boards of professional organizations in clinical genetics can uphold cytogenomic competence by providing adequate CLG training programs and attracting sufficient numbers of trainees.


Assuntos
Competência Clínica , Análise Citogenética/métodos , Testes Genéticos/métodos , Genômica/métodos , Análise Citogenética/normas , Testes Genéticos/normas , Genômica/normas , Humanos , Laboratórios Clínicos/normas